Mixed Binary Logging Format
When running in MIXED
logging format, the server automatically switches from statement-based to row-based logging under the following conditions:
- When a function contains
UUID()
. - When one or more tables with
AUTO_INCREMENT
columns are updated and a trigger or stored function is invoked. Like all other unsafe statements, this generates a warning ifbinlog_format = STATEMENT
.For more information, see , "Replication and
AUTO_INCREMENT
". - When the body of a view requires row-based replication, the statement creating the view also uses it. For example, this occurs when the statement creating a view uses the
UUID()
function. - When a call to a UDF is involved.
- When any
INSERT DELAYED
is executed for a nontransactional table. - If a statement is logged by row and the session that executed the statement has any temporary tables, logging by row is used for all subsequent statements (except for those accessing temporary tables) until all temporary tables in use by that session are dropped.
This is true whether or not any temporary tables are actually logged.
Temporary tables cannot be logged using row-based format; thus, once row-based logging is used, all subsequent statements using that table are unsafe. The server approximates this condition by treating all statements executed during the session as unsafe until the session no longer holds any temporary tables.
- When
FOUND-ROWS()
orROW_COUNT()
is used. (Bug #12092, Bug #30244) - When
USER()
,CURRENT-USER()
, orCURRENT_USER
is used. (Bug #28086) - When a statement refers to one or more system variables. (Bug #31168)
Exception. The following system variables, when used with session scope (only), do not cause the logging format to switch:
auto_increment_increment
auto_increment_offset
character_set_client
character_set_connection
character_set_database
character_set_server
collation_connection
collation_database
collation_server
foreign_key_checks
identity
last_insert_id
lc_time_names
pseudo_thread_id
sql_auto_is_null
time_zone
timestamp
unique_checks
For information about determining system variable scope, see , "Using System Variables".
For information about how replication treats
sql-mode
, see , "Replication and Variables". - When one of the tables involved is a log table in the
MariaDB
database. - When the
LOAD_FILE()
function is used. (Bug #39701)
A warning is generated if you try to execute a statement using statement-based logging that should be written using row-based logging. The warning is shown both in the client (in the output of SHOW WARNINGS
) and through the mysqld error log. A warning is added to the SHOW WARNINGS
table each time such a statement is executed. However, only the first statement that generated the warning for each client session is written to the error log to prevent flooding the log.
In addition to the decisions above, individual engines can also determine the logging format used when information in a table is updated. The logging capabilities of an individual engine can be defined as follows:
- If an engine supports row-based logging, the engine is said to be row-logging capable.
- If an engine supports statement-based logging, the engine is said to be statement-logging capable.
A given storage engine can support either or both logging formats. The following table lists the formats supported by each engine.
Storage Engine | Row Logging Supported | Statement Logging Supported |
---|---|---|
ARCHIVE
| Yes | Yes |
BLACKHOLE
| Yes | Yes |
CSV
| Yes | Yes |
EXAMPLE
| Yes | No |
FEDERATED
| Yes | Yes |
HEAP
| Yes | Yes |
InnoDB
| Yes | Yes when the transaction isolation level is REPEATABLE READ or SERIALIZABLE ; No otherwise.
|
MyISAM
| Yes | Yes |
MERGE
| Yes | Yes |
NDBCLUSTER
| Yes | No |
In MariaDB 5.6, whether a statement is to be logged and the logging mode to be used is determined according to the type of statement (safe, unsafe, or binary injected), the binary logging format (STATEMENT
, ROW
, or MIXED
), and the logging capabilities of the storage engine (statement capable, row capable, both, or neither). Statements may be logged with or without a warning; failed statements are not logged, but generate errors in the log. This is shown in the following decision table, where SLC stands for "statement-logging capable" and RLC stands for "row-logging capable".
Condition | Action | ||||
---|---|---|---|---|---|
Type | binlog_format
| SLC | RLC | Error / Warning | Logged as |
* | *
| No | No | Error: Cannot execute statement: Binary logging is impossible since at least one engine is involved that is both row-incapable and statement-incapable. | -
|
Safe | STATEMENT
| Yes | No | - | STATEMENT
|
Safe | MIXED
| Yes | No | - | STATEMENT
|
Safe | ROW
| Yes | No | Error: Cannot execute statement: Binary logging is impossible since BINLOG_FORMAT = ROW and at least one table uses a storage engine that is not capable of row-based logging.
| -
|
Unsafe | STATEMENT
| Yes | No | Warning: Unsafe statement binlogged in statement format, since BINLOG_FORMAT = STATEMENT
| STATEMENT
|
Unsafe | MIXED
| Yes | No | Error: Cannot execute statement: Binary logging of an unsafe statement is impossible when the storage engine is limited to statement-based logging, even if BINLOG_FORMAT = MIXED .
| -
|
Unsafe | ROW
| Yes | No | Error: Cannot execute statement: Binary logging is impossible since BINLOG_FORMAT = ROW and at least one table uses a storage engine that is not capable of row-based logging.
| - |
Row Injection | STATEMENT
| Yes | No | Error: Cannot execute row injection: Binary logging is not possible since at least one table uses a storage engine that is not capable of row-based logging. | - |
Row Injection | MIXED
| Yes | No | Error: Cannot execute row injection: Binary logging is not possible since at least one table uses a storage engine that is not capable of row-based logging. | - |
Row Injection | ROW
| Yes | No | Error: Cannot execute row injection: Binary logging is not possible since at least one table uses a storage engine that is not capable of row-based logging. | - |
Safe | STATEMENT
| No | Yes | Error: Cannot execute statement: Binary logging is impossible since BINLOG_FORMAT = STATEMENT and at least one table uses a storage engine that is not capable of statement-based logging.
| -
|
Safe | MIXED
| No | Yes | - | ROW
|
Safe | ROW
| No | Yes | - | ROW
|
Unsafe | STATEMENT
| No | Yes | Error: Cannot execute statement: Binary logging is impossible since BINLOG_FORMAT = STATEMENT and at least one table uses a storage engine that is not capable of statement-based logging.
| - |
Unsafe | MIXED
| No | Yes | - | ROW
|
Unsafe | ROW
| No | Yes | - | ROW
|
Row Injection | STATEMENT
| No | Yes | Error: Cannot execute row injection: Binary logging is not possible since BINLOG_FORMAT = STATEMENT .
| -
|
Row Injection | MIXED
| No | Yes | - | ROW
|
Row Injection | ROW
| No | Yes | - | ROW
|
Safe | STATEMENT
| Yes | Yes | - | STATEMENT
|
Safe | MIXED
| Yes | Yes | - | ROW
|
Safe | ROW
| Yes | Yes | - | ROW
|
Unsafe | STATEMENT
| Yes | Yes | Warning: Unsafe statement binlogged in statement format since BINLOG_FORMAT = STATEMENT .
| STATEMENT
|
Unsafe | MIXED
| Yes | Yes | - | ROW
|
Unsafe | ROW
| Yes | Yes | - | ROW
|
Row Injection | STATEMENT
| Yes | Yes | Error: Cannot execute row injection: Binary logging is not possible because BINLOG_FORMAT = STATEMENT .
| - |
Row Injection | MIXED
| Yes | Yes | - | ROW
|
Row Injection | ROW
| Yes | Yes | - | ROW |
When a warning is produced by the determination, a standard MariaDB warning is produced (and is available using SHOW WARNINGS
). The information is also written to the mysqld error log. Only one error for each error instance per client connection is logged to prevent flooding the log. The log message includes the SQL statement that was attempted.
If a slave server was started with --log-warnings
enabled, the slave prints messages to the error log to provide information about its status, such as the binary log and relay log coordinates where it starts its job, when it is switching to another relay log, when it reconnects after a disconnect, and so forth.