adeclip

Remove clipped samples from input audio.

Samples detected as clipped are replaced by interpolated samples using autoregressive modelling.

'w'

Set window size, in milliseconds. Allowed range is from 10 to 100. Default value is 55 milliseconds. This sets size of window which will be processed at once.

'o'

Set window overlap, in percentage of window size. Allowed range is from 50 to 95. Default value is 75 percent.

'a'

Set autoregression order, in percentage of window size. Allowed range is from 0 to 25. Default value is 8 percent. This option also controls quality of interpolated samples using neighbour good samples.

't'

Set threshold value. Allowed range is from 1 to 100. Default value is 10. Higher values make clip detection less aggressive.

'n'

Set size of histogram used to detect clips. Allowed range is from 100 to 9999. Default value is 1000. Higher values make clip detection less aggressive.

'm'

Set overlap method.

It accepts the following values:

'a'

Select overlap-add method. Even not interpolated samples are slightly changed with this method.

's'

Select overlap-save method. Not interpolated samples remain unchanged.

Default value is a.